Instru-Labs stock a large range of accessories for all of our products. Please contact us if you have any specific requirements.
2. Set the trigger level and display delay
Remove the rear panel to access the trigger level and display delay settings.
Installing the SoundSign
The SoundSign is very quick and simple to install
Installation of a Sound Sign is very simple.
Select the required trigger level, connect the 12v power supply to the unit and mount the SoundSign onto a wall.
When the noise level measured by the microphone reaches this level, the sign will illuminate and show the warning. The unit can also be set to keep the warning illuminated for up to 30 seconds after the level has fallen back below the trigger level.
This removes the sudden on-off indication that traditional noise warning signs often produce and which can cause confusion as to when PPE should be worn. The Sound Sign avoids these problems.
The sound level chosen for the trigger point can be set using either the simple level selection on the back of the unit or by using a calibrated Sound Level Meter to provide a reference measurement.
To install the SoundSign, follow these simple steps:
1. Open the box and check the contents
2. Set the trigger level and display delay
Remove the rear panel to access the trigger level and display delay settings.
SoundSign, The Noise Activated Warning Sign
Introducing a unique way to warn of noise levels
What is the SoundSign?
SoundSign™ is a highly visible noise activated warning sign that has been designed for use in environments where there is a need to clearly warn or indicate when a preset noise level is reached.
Benefits at a glance
- Lights up when a preset noise level is exceeded
- Quick & simple to install
- Trigger level from 40dB(A) to 114dB(A) for use in any environment
- High intensity white LED technology for high visual impact and a long operating life
- Use text and graphics to communicate specific noise level warnings
- 4 standard designs to cover all applications
When setting the trigger level, remember that this is the level at the microphone. Adjust the level to take account of any distance between the microphone and noise source.
For example, if the aim that the SoundSign illuminates at 85dB(A) at a nearby operator position, it may be necessary to measure the noise level at the operator position and at the position of the SoundSign and see if there is any difference. This can then be taken into account when setting the trigger level.
A range of accessories are available including a low cost Sound Level Meter which can help in the installation and setting of the trigger levels.
If a remote microphone is to be used, refer to section 5a below for details. Connecting the microphone extension cable before mounting the SoundSign on the wall will make installation simpler.
3. Connect the microphone and power supply
4. Mount the SoundSign onto a wall
The SoundSign can be mounted onto a wall using the supplied wall plus and screws. The installation guide contains a template to show the distance between the mounting holes on the back of the SoundSign unit.
It is possible to mount the SoundSign using other methods if it is not possible to use the supplied screws. The SoundSign is very light and so can be secured using industial strength Velcro or other similar products.
Please note that Cirrus Research plc accepts no responsibility for the use of any other installation or mounting other than the supplied screws and wall plugs. If you have any questions regarding the mounting of the SoundSign please contact us.
5. Optional Installation Steps
a. External Microphone & Cable
An extension cable can be used with the SoundSign to allow the microphone to be positioned remotely. This requires an optional preamplifier, microphone capsule and extension cable.
Connect the microphone extension cable to the microphone socket on the top of the SoundSign. Connect the preamplifier/microphone to the other end of the extension cable.
b. Data Logger
The CR:203 Data Logger plugs into the socket on the top of the SoundSign. This may be covered by a protective rubber cap which must be removed before the Data Logger is connected.
Before connecting the Data Logger, install the software onto a PC and connect the data logger to the software. This allows you to set the start time (up to 24 hours in advance) and to set the logging interval (1 second, 2 seconds, 10 seconds or 1 minute).
c. Remote Display Units
Remote Display can be connected to a Master Unit to replicate the information across a wider area.
Mounting a Remote Unit is the same as for the Master Units and the connection between a Remote and Master unit is made using the supplied 10m cable. Up to 3 Remote Units can be connected to a single Master Unit.
In addition to the traditional Noise at Work style sign, the Sound Sign is also available with a range of other graphics and text which allows it to be used in environments where the noise levels may not reach those where hearing protection is required, but where there is still a need to warn or indicate excessive sound levels.
Ideal for Noisy Environments
Use the SoundSign™ in noisy environments such as factories, workshops, pubs and nightclubs to warn when noise levels become too high and indicate when hearing protection must be worn.
Ideal for Quiet Environments
Use SoundSign™ in quiet locations such as schools, hospitals and libraries to indicate when noise levels must be kept down.
Find out more
Contact us about how to install SoundSign™ in your specific environment.
To view our complete noise instrument product range, please view the rest of our website.